MCU Simulator Robotic and Embedded System Laboratory
← Open the simulator
Documentation

Troubleshooting

Compile errors, a board that does nothing, MQTT and HTTP problems, sign-in, and how to solve them.

Most problems show up in one of three places: the red marks in the editor and Compiler output, the Serial monitor, and the Network log. Wiring problems are listed on the part cards.

The sketch does not compile

MessageWhat to do
… was not declared in this scopeA typo, a missing #include, or a variable declared inside another function.
fatal error: XYZ.h: No such file or directoryThe library is not available: see the list of libraries.
A message naming ESP8266WiFi.h or WiFi.hThe header belongs to the other chip family: choose the matching board, or use the header the message names.
Too many compilesAt most 5 compilations per minute: wait a moment.
Compilation stopped: it took longer than 60 sVery large sketches or tables; try again, or make it smaller.

The board runs but nothing happens

  • The part has no power: its card says so and the Diagram shows no power. Connect VCC and GND.
  • Wrong pin: the GPIO in the sketch is not the one on the part card. The pin map in the board panel shows which part is on which pin.
  • Input-only pin (GPIO 34–39 on ESP32) used as an output: the serial monitor warns once; choose another pin.
  • Analog value is always 0 on ESP32 while Wi-Fi is on: the pin is on ADC2. Use an ADC1 pin (GPIO 32–39 on the DevKit).
  • I2C part not found: check its address in the sketch against the part card, that SDA and SCL are connected, and run i2c_scanner.ino. Two parts at the same address are an error on the card.
  • Button reads the wrong way: the simulator's push button connects the pin to GND; use INPUT_PULLUP and check for LOW.

MQTT does not connect

In the serial monitorMeaning
state 5 / not authorisedWrong access token, or the topic does not contain it. Use 📟 Devices → Token only to fill it in.
state -2 / connection failedThe broker has no WebSocket address in Settings, or cannot be reached. The Network log names the address tried.
Connects, then dropsmqtt.loop() is not called often enough, or two boards use the same client ID.
Messages larger than 256 bytes vanishThe PubSubClient buffer: call mqtt.setBufferSize(1024) before connecting.

The device on IoT Platform stays offline while the board is not connected; after Stop it goes offline through its Last Will.

HTTP requests fail

  • A negative code and the simulator only allows HTTP requests to: … in the Network log: the server only forwards to iot.reslab-csub.cloud.
  • Code 301 or 302: the address redirects (often http:// to https://); use the final address.
  • request body too large: at most 768 KB, e.g. lower the camera quality or frame size.

Signing in and devices

  • Your IoT Platform session has ended: sign in again; your open work in this browser is kept.
  • Devices shows Allow on IoT Platform: the simulator may not read your devices yet; allow it once.
  • A device has no Open template: you can only view it; its owner can make you an editor.

Browser and display

  • Camera does not start (ESP32-CAM): allow the camera for this site in the browser, or choose Test pattern.
  • Old version after an update: reload with Ctrl+Shift+R.
  • Simple editor instead of the code editor: the editor could not load; reload the page.
  • Lost work? The open project is kept in this browser only; save it with Projects or Export to have it elsewhere. Another browser or a private window starts empty.